Vista de pagina 56
Reference MVI56-S3964RT TControlLogix PlatformT
TSiemens 3964R ProtocolT
ProSoft Technology, Inc. Page 57 of 78
Send Block for Module to send to CP (Block 1)
Offset Data Length
0 9X1X 1
1 Header 10
11 Data 50
Send Block for Module to send to CP (Blocks 2 to 4)
Offset Data Length
0 9X2X, 9X3X, 9X4X 1
1 Data 60
Request for data Block from Module to respond to CP
Offset Data Length
0 910X 1
1 Reserved 2
3 1145h 1
4 Data Block (DB) 1
5 Data Word (DW) 1
6 Number of Data Words 1
7 Coordination Bytes 1
8 Data Type (4Dh/44h) 1
9 to 12 Reserved 4
Receive Data from CP (First Block)
Offset Data Length
0 910X 1
1 Reserved 1
2 Data Block 1 1
3 1141h/11FFh 1
4 Data Block (DB) 1
5 Data Word (DW) 1
6 Number of Data Words 1
7 Coordination Bytes 1
8 Data Type (4Dh/44h) 1
9 to 12 Reserved 4
13 Data 49
Receive Data from CP (Blocks 2 to 4)
Offset Data Length
0 910X 1
1 Reserved 1
2 Data Block (2 to 4) 1
3 Data 59