ProSoft Technology ProLinx S3964R Manual de usuario Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
Configure the Gateway S3964R ProLinx Gateway
Driver Manual Siemens 3964R Protocol
ProSoft Technology, Inc. Page 19 of 64
April 14, 2009
2.2 Common Configuration
2.2.1 Data Map
The [DATA MAP] section allows you to copy data between areas in the module's
internal database. .
You can copy to 100 registers at a time, and you can configure up to 200
separate copy commands.
For example, you can copy data from the error or status tables in upper memory
to internal database registers in the User Data memory area. You can also
rearrange the byte or word order during the copy process so that data such as
floating point values can be converted to the correct format for a specific
protocol.
You can also use the Data Map to build a specific block of data to be used by
any of the protocols that reside in the S3964R gateway.
Vista de pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 63 64

Comentarios a estos manuales

Sin comentarios