92 Publication LOGIX-AP010B-EN-P - May 2010
Chapter 3 Software Conversions Instructions
The RSLogix 5000 Convert to Integer (FRD) instruction performs the same
function.
S5 Instruction Description
DEF Convert a 16 bit fixed point from BCD into binary
DED Convert a 16 bit fixed point from BCD into binary
BCD to Integer
S5 RSLogix 5000
DW64 data_word1
DW78 data_word2
S5 Statement List
16 bit fixed point numbers
RSLogix 5000 Structured Text
LDW64
DEF
T DW78
This instruction is not available in structured text format.
SIMATIC S5 - Ladder
RSLogix 5000 - Ladder