Ethernet Protocol Communication Solutions
EtherNet/IP Connectivity for SLC and PLC-5®
Supports PLC-5 family, SLC 5/02,03, 04, & 05
Resides in any local slot (SLC and/or remote
rack PLC-5)
Backplane data transfer
Client/Server - Read/Write Data
10/100 Mbps
Program Over Ethernet via Serial CH0 Connection
Example Application: User requires addition of EtherNet/IP
connectivity to SLC and/or PLC. Installations where application
requires having both EtherNet/IP and DH+™ or DH-485. For
SLC 5/05 or PLC-5-E users, add additional Ethernet connectivity.
Solution: MVI46-DFNT for SLC 500
MVI69-DFNT for CompactLogix
MVI71-DFNT for PLC-5
Modbus TCP/IP Connectivity
4000 word module memory usage completely user-denable
10/100 Mbps Ethernet compatible interface
Backplane compatible, resides in any slot
Example Application: User requires connectivity from ControlLogix™, PLCs, or SLCs directly to
Modbus TCP/IP network.
Solution: MVI56-MNET for ControlLogix
MVI56-MNETC for ControlLogix, Client Only
MVI46-MNET for SLC™ 500
MVI46-MNETC for SLC 500 client only
MVI69-MNET for CompactLogix™
MVI71-MNET for PLC-5™
Quantum
Processor
PLC-5 SLC 500 ControlLogix
Modbus TCP/IP
6
Wastewater Treatment
Made Easy with Modbus
Elian Jessen of HV-Turbo in Denmark
recently delivered and installed compressors
for the Jerusalem Wastewater Treatment
Plant. The existing plant network was
Genius-bus. In order to send and receive
information between SCADA and the HV-
Turbo main panel, a GE-Fanuc 90-30 PLC
was installed in the HV-Turbo main next
to the already installed Allen-Bradley SLC.
Both the A-B SLC and the GE PLC needed to
communicate via Modbus. “The customer
called me and said they had to communicate
with Modbus and was that possible to do
with an Allen-Bradley SLC 500?” said Elian
Jessen of HV-Turbo. “I knew about ProSoft
Technology® so I told him ‘Yes, no problem.’
ProSoft Technology kindly forwarded to us
a manual on the module so that HV-Turbo
could see it was not that complicated to set
up the communication.”
ProSoft Technology’s 3150-MCM module
was chosen to be the master for the
communication, transferring vital data
between SCADA and the main PLC via the
GE-Fanuc controller.
“Since this project was completed, we have
ordered 25 similar modules for connecting
some of our other specially designed control
panels to our customer’s main panels in six
renery plants in India with great success
using our own multipurpose software for the
MCM,” said Jessen.
Application Story
High-Speed Wireless EtherNet/IP Server for ControlLogix
High-speed Wi-Fi wireless connectivity
Links wireless laptops, PDAs and workstations for
PLC programming and HMI
Wireless range up to 1000 feet (330 m); may be
extended with access points and repeaters
Wireless connectivity to other networks (Bridging)
Wirelessly congure ControlNet, Ethernet and
DeviceNet
Supports RSLogix 5000®, RSView®, RSLinx®
and RSNetworx®
Example Application: User requires wireless programming
and/or HMI application, arc ash safety procedures or
separation from the wired plant or business network.
Solution: MVI56-WA-EIP
Laptop with Wi-Fi
running RSLogix 5000
Programming Software
Laptop with Wi-Fi running
RSView 32 HMI Software
ControlLogix
PDA or Pocket PC
with HMI Software
Wireless Wi-Fi Link