ProLinx-HART ♦ ProLinx Gateway Reference
HART Master with Analog I/O Driver Manual
ProSoft Technology, Inc. Page 71 of 104
October 13, 2011
COMMAND 49 - Write PV Sensor Serial Number
Description
This command changes the sensor serial number of the Primary Variable.
Write Parameters
Word High Byte Low Byte
0 Sensor Serial Number (Byte 0) Sensor Serial Number (Byte 1)
1 Sensor Serial Number (Byte 2) Sensor Serial Number (Byte 2)
Floating Point Data Returned
NONE
Integer Data Returned
Word High Byte Low Byte
0 STATUS WORD
1 Sensor Serial Number (Byte 0) Sensor Serial Number (Byte 1)
2 Sensor Serial Number (Byte 2) 0