MVI69E-MBS ♦ CompactLogix Platform Reference
Communication Module User Manual
ProSoft Technology, Inc. Page 145 of 162
January 6, 2014
Block 9959: Request from Module to Processor
Bit mask to use with the data set. Each bit to be considered with the data set has
a value of 1 in the mask. Bits to ignore in the data set has a value of 0 in the
mask.
Where n = 60, 120, or 240 depending on the Block Transfer Size parameter.
The ladder logic is responsible for parsing and copying the received message
and performing the proper control operation as expected by the Master device.
The processor must then respond to the pass-through control block with a write
block with the following format.
Block 9959: Response from Processor to Module
This informs the module that the command has been processed and can be
cleared from the pass-through queue.
7.4.17 Pass-through Formatted Block for Function 22
Block 9960: Pass-through Formatted Block for Function 22
Block 9960: Request from Module to Processor
Number of word registers in Modbus data set
Starting address for Modbus data set
Data (Length in words = n - 2)
Where n = 60, 120, or 240 depending on the Block Transfer Size parameter.