MVI69E-MBS CompactLogix Platform Reference
Communication Module User Manual
ProSoft Technology, Inc. Page 149 of 162
January 6, 2014
7.4.22 Reset Status Block
Block 9997: Reset Status Block
This block resets the module, port 1, and/or port 2 status.
Block 9997: Request from Processor to Module
Offset
Description
0
Write Block ID: 9997
1
Reset Module status (0=no, else yes)
2
Reset Port 1 status (0=no, else yes)
3
Reset Port 2 status (0=no, else yes)
4 to (n-1)
Spare
Where n = 60, 120, or 240 depending on the Block Transfer Size parameter.
Block 9997: Response from Module to Processor
Offset
Description
0
Read Block ID: 9997
1
Write Block ID: To be used by the processor in its next Write block.
2 to (n-1)
Spare
7.4.23 Warm-boot Control Block
Block 9998: Warm-boot Control Block
If the CompactLogix sends a block number 9998, the module performs a warm-
boot operation. The module reconfigures the communication ports and reset the
error and status counters.
Block 9998: Request from Processor to Module
Offset
Description
0
Write Block ID: 9998
1 to (n-1)
Spare
Where n = 60, 120, or 240 depending on the Block Transfer Size parameter.