Backplane Communication PTQ-AFC Modicon Quantum Platform
User Manual Liquid and Gas Flow Computer for Hydrocarbon Products
Page 172 of 259 ProSoft Technology, Inc.
June 23, 2011
9.1.2 Supervisory Input Block
The Supervisory Input Block is automatically copied from the PTQ-AFC to the
Quantum processor. It contains several types of status data information from the
module as shown in the following table.
Offset
Description Type Comments
0
Wallclock set fail Error 0 = success
1 = cannot set clock (bad clock values?)
2 = list entry allocation failure -- probably
wallclock block located out of range
3 = wallclock block not defined
1
Event log full error Error 0 = no error
1 = error -- meter disable/enable not
performed
2
Master transaction logic
error
Error 0 = no error
1 = error -- see error code in Modbus Master
block
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
9
Reserved
10
Wallclock not set Status 0 or 1
11
Meter in alarm Status bitmap of meters in alarm
12
Pass-thru transaction
pending
Status 0 or 1
13
Reserved
14
Reserved
15
Reserved
16
Reserved
17
Reserved
18
Reserved
19
Reserved
20
PTQ-AFC Released Status
21
Checksum alarm Status
22
Reserved
23
Reserved
24
Quantum halted, offline,
or missing
Status
25
Measurement
configuration changed
Status
26
Power up Status
27
Cold start Status
28
Reserved
29
Version compatibility
code
Status 0: version 2.04 or earlier
1: version 2.05 or later