AN-X-DCSNet2 Communication Module User Manual
Page 6 AN-X-DCSNet2 November 2011 The passive tap has two BNC connectors for connection to the coaxial cables and terminating loads. The network
AN-X-DCSNet2 Page 7 Ethernet Configuration The AN-X-DCSNet2 module connects a computer or other device on Ethernet to a Reliance DCS network. Befor
Page 8 AN-X-DCSNet2 November 2011 AN-X is using this temporary IP address, it repeatedly flashes the SYS LED three times followed by a pause.
AN-X-DCSNet2 Page 9 1. Select the Ethernet adapter that’s connected to the AN-X. In most cases there will be just one Ethernet adapter in the com
Page 10 AN-X-DCSNet2 November 2011 The preferred method is to cycle power on the AN-X. Select the first option on the screen, power off the A
AN-X-DCSNet2 Page 11 If the AN-X does not enter boot mode within about 10 seconds, return to the previous screens and check the entries. The AN-
Page 12 AN-X-DCSNet2 November 2011 Enter a Host Name for the AN-X. This name is used internally by AN-X and may be used to identify the AN-X if
AN-X-DCSNet2 Page 13 Click the Properties button. Double click on Internet Protocol (TCP/IP).
Page 14 AN-X-DCSNet2 November 2011 In this example, we will assign the computer an IP address of 192.168.0.10 Set the Subnet mask to 255.255.255
AN-X-DCSNet2 Page 15 Select Utilities/Select An AN-X and enter the MAC Address and IP address. Click OK to accept the setting. Select Utilities/AN
Page 2 AN-X-DCSNet2 November 2011 Because of the variety of uses for the products described in this publication, those responsible for the appl
Page 16 AN-X-DCSNet2 November 2011 Reconfiguring an AN-X from an Unknown State It sometimes happens that an AN-X has been previously configure
AN-X-DCSNet2 Page 17 DCSNet Configuration You set the DCS mode of operation (master or slave) and the drop number and depth using the web interface
Page 18 AN-X-DCSNet2 November 2011 Using the AutoMax Programming Software Any computer with Ethernet access can use an AN-X-DCSNet module to con
AN-X-DCSNet2 Page 19 Configuring the Programming Software To configure the AutoMax Programming Executive to use AN-X: 1. Run the Programming Exe
Page 20 AN-X-DCSNet2 November 2011 3. Set the Communications Type to PC Link Interface Module. 4. Set the Drop to match the AN-X drop number
AN-X-DCSNet2 Page 21 If multiple copies of the Programming Executive attempt to program an AutoMax through the same AN-X-DCSNet, the AutoMax sees t
Page 22 AN-X-DCSNet2 November 2011 Scheduled Data with a ControlLogix AN-X-DCSNet2 exchanges scheduled data with a ControlLogix processor. It su
AN-X-DCSNet2 Page 23 2. Map DCS data to the scheduled data and save the mappings as a comma separated variable (CSV) file 3. Send the configurati
Page 24 AN-X-DCSNet2 November 2011 Enter the Name. Use the host name you assigned to AN-X when you configured its IP properties. Set the Slot
AN-X-DCSNet2 Page 25 Set the Name and Description as desired. Set the Comm Format to Data – INT. Set the other parameters as shown. Set the Slot
AN-X-DCSNET2 MODULE OVERVIEW 2 Hardware Features 3 Package Contents 3 Other Requirements 3 Modes of Operation 4 INSTALLATION 5 Prevent Electro
Page 26 AN-X-DCSNet2 November 2011 AN-X supports RPIs from 5 to 750 ms. Select an RPI appropriate to the DCS network scan time and to your app
AN-X-DCSNet2 Page 27 Input Only Connection The AN-X-DCSNET2 supports one input only connection from a ControlLogix processor. The ControlLogix pro
Page 28 AN-X-DCSNet2 November 2011 Set the parameters as shown. Set the Comm Format to Input Data – INT. Set the Slot to 0 for the first c
AN-X-DCSNet2 Page 29 Mapping the DCS Data You define the DCS data that is exchanged between the AN-X and the ControlLogix processor in a comma-d
Page 30 AN-X-DCSNet2 November 2011 The ClxPrefix can be used to distinguish between AN-X modules when a ControlLogix processor communicates with
AN-X-DCSNet2 Page 31 depth. For example, if the drop number is 7 and the depth is 3, only drops 7, 8, and 9 can be used in output data mappings. I
Page 32 AN-X-DCSNet2 November 2011 The units for the times are 0.1 milliseconds. A value of 87 means 8.7 ms. To map the statistics for a given
AN-X-DCSNet2 Page 33 ,ConnStats15 Sample File – DCS Master The following sample file shows how data is mapped for an AN-X configured as a DCS mast
Page 34 AN-X-DCSNet2 November 2011 Viewing the Current Configuration To view the configuration in an AN-X module, access the AN-X using the web
AN-X-DCSNet2 Page 35 In the web interface, select Automation Network/View Configuration Files. There are two sets of files, one for exclusive owner
Page 4 AN-X-DCSNet2 November 2011 Reference 23 Configuring AN-X in RSLogix 5000 23 Exclusive Owner Connection 23 Input Only Connection 27 Ma
Page 36 AN-X-DCSNet2 November 2011 Using AnxInit AnxInit is a 32-bit Windows application supplied with AN-X to perform the following functions:
AN-X-DCSNet2 Page 37 AN-X Log Locating Available AN-X Modules To locate all accessible AN-X modules on the Ethernet network, select Utilities/Loc
Page 38 AN-X-DCSNet2 November 2011 Selecting an AN-X Before you can perform an operation on an AN-X, you must select it. Choose Utilities/Sele
AN-X-DCSNet2 Page 39 Enter a Host Name for the AN-X. This name is used internally by AN-X and may be used to identify the AN-X if you have a DNS
Page 40 AN-X-DCSNet2 November 2011 AN-X Info The Utilities/AN-X Info command provides information about the currently selected AN-X in the log
AN-X-DCSNet2 Page 41 The Utilities/Read Kernel Parameters command leaves the AN-X running the boot code. Use the Utilities/Restart AN-X command t
Page 42 AN-X-DCSNet2 November 2011 Update Firmware There are two ways to update all the firmware in an AN-X module. 1. The Configuration/Firm
AN-X-DCSNet2 Page 43 1. Select the Ethernet adapter that’s connected to the AN-X. In most cases there will be just one Ethernet adapter in the co
Page 44 AN-X-DCSNet2 November 2011 The preferred method is to cycle power on the AN-X. Select the first option on the screen and click the Ne
AN-X-DCSNet2 Page 45 If the AN-X does not enter config mode within about 60 seconds, return to the previous screens and check the entries. Click
USING THE WEB INTERFACE 48 DCSNet Configuration 48 Configure ControlLogix Support 50 View Configuration Files 50 View Active Configuration 51 Mo
Page 46 AN-X-DCSNet2 November 2011 • ControlLogix configuration Update Firmware Command The Utilities/Update Firmware command updates all the
AN-X-DCSNet2 Page 47 This command resets the AN-X. You will receive a warning and be given the opportunity to Cancel the command. You do not h
Page 48 AN-X-DCSNet2 November 2011 Using the Web Interface The AN-X module contains a webserver capable of communicating with standard web brows
AN-X-DCSNet2 Page 49 AN-X-DCSNet can be used as a DCS master or slave. Check Master or Slave to select which one you want. If the AN-X-DCSNet is
Page 50 AN-X-DCSNet2 November 2011 Configure ControlLogix Support AN-X can exchange scheduled data with a ControlLogix processor over Ethernet.
AN-X-DCSNet2 Page 51 Click on the links to view the files using the application that is associated with CSV files. Right click on the links to ret
Page 52 AN-X-DCSNet2 November 2011
AN-X-DCSNet2 Page 53 Monitor DCS Data To use the web interface to view the current DCS network data on the AN-X, select Automation Network/Monitor
Page 54 AN-X-DCSNet2 November 2011 Log Files AN-X maintains various logs to record diagnostic and error messages. Use the Log Files menu in the
AN-X-DCSNet2 Page 55 Technical support will provide the password and supply detailed information on any further steps. AN-X IP Configuration You
AN-X-DCSNet2 Module Overview The AN-X-DCSNet2 firmware runs on an AN-X AutoMax communications module and connects a computer or other device to a Re
Page 56 AN-X-DCSNet2 November 2011 You can configure the AN-X to use DHCP or to use a static IP address. Click SUBMIT to set the parameters
AN-X-DCSNet2 Page 57 Restart AN-X Module The Restart AN-X Module command is password protected and is intended for technical support.
Page 58 AN-X-DCSNet2 November 2011 Troubleshooting LEDs The AN-X-DCSNet has LEDs that indicate the state of the Ethernet connection, the conne
AN-X-DCSNet2 Page 59 At startup, the SYS LED sequence is: • boot code starts – fast flashing red • boot code loads a kernel – solid red • if the
Page 60 AN-X-DCSNet2 November 2011 In the drop status table, register 4 contains status for drops 0 to 15, bit 0 corresponds to drop 0 (the mas
AN-X-DCSNet2 Page 61 Updating the Firmware The AN-X operating software consists of several parts: • boot code, runs at startup • configuration ke
Page 62 AN-X-DCSNet2 November 2011 Specifications Parameter Specification Function Bridge between Ethernet and AutoMax DCS network Typical Po
AN-X-DCSNet2 Page 63 Support How to Contact Us: Sales and Support Sales and Technical Support for this product are provided by ProSoft Technology.
Page 64 AN-X-DCSNet2 November 2011 Warranty Quest Technical Solutions warrants its products to be free from defects in workmanship or material u
AN-X-DCSNet2 Page 3 Hardware Features The module has: • LEDs to indicate the status of the connection to the Ethernet, its own internal state,
Page 4 AN-X-DCSNet2 November 2011 To exchange scheduled data with a ControlLogix processor over Ethernet requires: • version 12 or above of RSL
AN-X-DCSNet2 Page 5 Installation Prevent Electrostatic Discharge The module is sensitive to electrostatic discharge. WARNING! Electrostatic discha