Configuring the MVI69-GSC Module MVI69-GSC ♦ CompactLogix or MicroLogix Platform
User Manual Generic ASCII Serial Communication Module
Page 32 of 102 ProSoft Technology, Inc.
September 24, 2010
2.3 Downloading the Sample Program to the Processor
Note: The key switch on the front of the CompactLogix processor must be in the REM or PROG
position.
1 If you are not already online to the processor, open the C
OMMUNICATIONS
menu, and then choose D
OWNLOAD
.
RSLogix will establish communication
with the processor.
2 When communication is established, RSLogix will open a confirmation dialog
box. Click the D
OWNLOAD
button to transfer the sample program to the
processor.
3 RSLogix will compile the program and transfer it to the processor. This
process may take a few minutes.
4 When the download is complete, RSLogix will open another confirmation
dialog box. Click OK
to switch the processor from PROGRAM
mode to RUN
mode.
Note: If you receive an error message during these steps, refer to your RSLogix documentation to
interpret and correct the error.