60 Words Block Format for Mailbox In Message (Input Image)
When the Block Transfer Size = 60, it takes three Output blocks to form one
complete mailbox message request. Each Output block will be responded to with
a corresponding Input block with the same ID number.
Note: Since the same three Output Block IDs are always used for 60-word block format requests,
the Input Block IDs will always be the same three numbers, as well, 100, 101, and 102.
Word Offset
Start End Name Description
0 0 Block ID Block number 100
1 1 Output Index
Index of Output image to receive (1 to 16 for data, 0
or -1 if no data)
2 61 Mailbox Message
Mailbox input message from module (first 60 words of
mailbox message)
Word Offset
Start End Name Description
0 0 Block ID Block number 101
1 1 Output Index
Index of Output image to receive (1 to 16 for data, 0
or -1 if no data)
2 61 Mailbox Message
Mailbox input message from module (second 60
words of mailbox message)
Word Offset
Start End Name Description
0 0 Block ID Block number 102
1 1 Output Index
Index of Output image to receive (1 to 16 for data, 0
or -1 if no data)
2 25 Mailbox Message
Mailbox input message from module (last 24 words of
mailbox message)
26 61 Reserved Reserved for future use