Mailbox Messaging MVI69-PDPMV1 ♦ CompactLogix or MicroLogix Platform
User Manual PROFIBUS DPV1 Master
Page 98 of 225 ProSoft Technology, Inc.
July 8, 2011
4.4.5 Mailbox Message: Set Slave Address
This command makes it possible to set the node address of a specified slave, if
the slave supports this feature.
Note: The message data size depends on the actual slave implementation. Range 0 to 240 bytes.
Parameter Description
Command Initiator Application
Command Name SET SLAVE ADDRESS
Command Number 0600h
Fragmented No
Extended Header Data Fault information may be returned in the header of the response.
Command and Response Layout: Set Slave Address
Command Response
Message ID
(ID)
(ID)
Message information 4002h
0002h
Command 0006h
0006h Set Slave Address
Data size (Size of data)
(Size of data) No. of Slave Data bytes (n)
Frame count 0001h
0001h
Frame number 0001h
0001h
Offset high 0000h
0000h
Offset low 0000h
0000h
Extended word 1 Current
Slave Addr.
New Slave
Address
Current
Slave Addr.
New Slave
Address
Extended word 2 Slave Ident Number
Slave Ident Number
Extended word 3 No_add_
Chg
- No_add_
Chg
Extended word 4 -
-
Extended word 5 -
Error Code 1
Error Code 2
Extended word 6 -
Error Code 3
Error Code 4
Extended word 7 -
Return Code
Extended word 8
Fault Information
Message Data byte 1 Slave Data 1
Slave Data 1
Message Data byte 2 Slave Data 2
Slave Data 2
Message Data byte 3 Slave Data 3
Slave Data 3
... ...
...
Message Data byte "n" Slave Data n
Slave Data n